SkyFlex is a tough, flexible air barrier for use in residential and commercial building applications. The product consists of two layers of aluminum deposited on a layer of woven polyethylene. When exposed to air films or enclosed air spaces in building cavities, SkyFlex’s low-emittance exterior layers reduce radiant heat transfer.
SkyFlex is designed to be used as a primary air enclosure boundary between conditioned and unconditioned air in the building envelope. Air barrier materials are measured by air permeance. An air barrier permeance equal to or less than 0.02L(sxm2)@75 Pa, as tested in accordance with ASTM 2178, qualifies as an air barrier material. SkyFlex’s air permeance levels fall below 0.02L(sxm2)@75 Pa, making it a very effective air barrier material.
As a Class I vapor retarder, this product is also effective for reducing vapor permeability. SkyFlex has a vapor permeability of 0.01 perms making it an effective vapor retarder.
When installed in walls, ceiling or floor joists, SkyFlex’s low-emittance exterior layers can boost the R-Value, or thermal resistance, of the wall system. When used for one side exposed to the attic, SkyFlex adds 1.7 R-Value. When 0.75 inches is installed in an enclosed air space, the product adds 2.9 R-Value; for 1.50 inches of Sky Flex, the added R-Value is 2.6. R-Values can be calculated using the ASHRAE book of fundamentals.
Width of Roll |
Solid - 48" / 51" VT - 48" |
|||
Diameter |
Solid - 5" VT - 5" |
|||
Lineal Footage |
Solid - 125' / 118' VT - 125' |
|||
Coverage (Sqft) |
Solid - 500 VT - 500 |
|||
Weight (lbs) |
Solid - 10 VT - 10 |
Test Method | Description | Results |
---|---|---|
ASTM E2178 | Air Permeability |
Solid - <0.02 L/(s•m²)@75 Pa VT - <0.004 L/(s•m²)@75 Pa |
ASTM E96 | Water Vapor Permeance |
Solid - <0.1 VT - >10 |
ASTM C1371 | Emissivity |
Solid - 0.05 VT - 0.20 |
ASTM E84 | Flame Spread |
Solid - <25 VT - <25 |
ASTM E84 | Smoke Developed |
Solid - <50 VT - <50 |
Wall Exposed to Attic |
Solid - R-1.7 VT - R-1.4 |
|
0.75" Enclosed Air Space |
Solid - R-2.9 VT - R-2.0 |
|
1.50" Enclosed Air Space |
Solid - R-2.6 VT - R-1.8 |
|
Aluminum Foil | 0.03 - 0.05 | |
Other Low-e Material | 0.11 - 0.25 | |
Other Common Building Materials including wood, masonry and standard mass insulation |
0.82 - 0.90 |
SkyFlex is a tough, flexible air barrier for use in residential and commercial building applications. The product consists of two layers of aluminum deposited on a layer of woven polyethylene. When exposed to air films or enclosed air spaces in building cavities, SkyFlex’s low-emittance exterior layers reduce radiant heat transfer.
SkyFlex is designed to be used as a primary air enclosure boundary between conditioned and unconditioned air in the building envelope. Air barrier materials are measured by air permeance. An air barrier permeance equal to or less than 0.02L(sxm2)@75 Pa, as tested in accordance with ASTM 2178, qualifies as an air barrier material. SkyFlex’s air permeance levels fall below 0.02L(sxm2)@75 Pa, making it a very effective air barrier material.
As a Class I vapor retarder, this product is also effective for reducing vapor permeability. SkyFlex has a vapor permeability of 0.01 perms making it an effective vapor retarder.
When installed in walls, ceiling or floor joists, SkyFlex’s low-emittance exterior layers can boost the R-Value, or thermal resistance, of the wall system. When used for one side exposed to the attic, SkyFlex adds 1.7 R-Value. When 0.75 inches is installed in an enclosed air space, the product adds 2.9 R-Value; for 1.50 inches of Sky Flex, the added R-Value is 2.6. R-Values can be calculated using the ASHRAE book of fundamentals.
Width of Roll |
Solid - 48" / 51" VT - 48" |
|||
Diameter |
Solid - 5" VT - 5" |
|||
Lineal Footage |
Solid - 125' / 118' VT - 125' |
|||
Coverage (Sqft) |
Solid - 500 VT - 500 |
|||
Weight (lbs) |
Solid - 10 VT - 10 |
Test Method | Description | Results |
---|---|---|
ASTM E2178 | Air Permeability |
Solid - <0.02 L/(s•m²)@75 Pa VT - <0.004 L/(s•m²)@75 Pa |
ASTM E96 | Water Vapor Permeance |
Solid - <0.1 VT - >10 |
ASTM C1371 | Emissivity |
Solid - 0.05 VT - 0.20 |
ASTM E84 | Flame Spread |
Solid - <25 VT - <25 |
ASTM E84 | Smoke Developed |
Solid - <50 VT - <50 |
Wall Exposed to Attic |
Solid - R-1.7 VT - R-1.4 |
|
0.75" Enclosed Air Space |
Solid - R-2.9 VT - R-2.0 |
|
1.50" Enclosed Air Space |
Solid - R-2.6 VT - R-1.8 |
|
Aluminum Foil | 0.03 - 0.05 | |
Other Low-e Material | 0.11 - 0.25 | |
Other Common Building Materials including wood, masonry and standard mass insulation |
0.82 - 0.90 |